Specifications Top

The Reliable, Repeatable, Accurate Way to Check Bearings and Overall Vibration

Make go or no-go maintenance decisions with confidence. The Fluke 805 Vibration Meter is the most reliable vibration screening device available for frontline mechanical troubleshooting teams that need repeatable, severity-scaled readings of overall vibration and bearing condition.

What Makes the 805 the Best Choice?

  • A meter – not a pen – that measures overall vibration as well as specific variables like bearing condition and temperature, to provide a more complete picture
  • A combination vibration and force sensor tip that compensates for user variance (force or angle) yielding accurate, repeatable readings
  • A four-level severity scale and onboard processor calculate bearing condition and overall vibration using easy-to-understand textual alerts (Good, Satisfactory, Unsatisfactory, Unacceptable)
  • Sensor sensitivity can read a wide range of frequencies (10 to 1,000 Hz and 4,000 to 20,000 Hz) covering most machine and component types
  • Straight-forward user interface that minimizes the user inputs to RPM range and equipment type

Features and Benefits

  • Innovative sensor design helps minimize measurement variations caused by device angle or contact pressure
  • Consistent data quality at both low and high frequency ranges
  • Four-level scale indicates severity of problems for overall vibration and bearing condition
  • Exportable data via USB
  • Trending in Microsoft® Excel using built-in templates
  • Overall vibration measurement (10 Hz to 1,000 Hz) for acceleration, velocity and displacement units of measurement for a wide variety of machines
  • Crest Factor+ provides reliable bearing assessment using direct sensor tip measurements between 4,000 Hz and 20,000 Hz
  • Colored lighting system (green, red) and on-screen comments indicate how much pressure needs to be applied to take measurements
  • Temperature measurement with Infrared Temperature Sensor increases diagnostic capabilities
  • On-board memory holds up to 3,500 measurements
  • Audio output for listening to bearing tones directly
  • External accelerometer support for hard to reach locations
  • Flashlight for viewing measurement locations in dark areas
  • Large screen with high resolution for easy navigation and viewing

Use the 805 to check the following machine categories:

  • Chillers (refrigeration)
  • Fans
  • Cooling tower drives
  • Centrifugal pumps
  • Positive displacement pumps
  • Air compressors
  • Blowers
  • Generic gearboxes (rolling element bearings)
  • Machine tools (motor, gearboxes, spindles, etc.)

What is Crest Factor+?

Vibration meter measurements

Crest Factor+ is a new proprietary algorithm (or technology) that takes the confusion out of bearing assessment. The original Crest Factor is used by vibration analysts to identify bearing faults. It is defined as the ratio of the peak value/RMS value of a time domain vibration signal.

A key limitation of the original Crest Factor algorithm is that it does not increase linearly as the bearing degrades, making it very difficult to determine the severity of mechanical issues. In fact, the Crest Factor can actually decrease as a bearing nears catastrophic failure due to large RMS values.

In order to overcome this limitation, Fluke uses a proprietary algorithm known as Crest Factor+ (CF+). CF+ values range from 1 to 16. As the bearing condition worsens, the CF+ value increases, ensuring the user is easily able to recognize the severity of the problem. To make things even simpler, Fluke has also included a four-level severity scale that identifies the bearing health as Good, Satisfactory, Unsatisfactory or Unacceptable.

Exporting and trending with the 805


Trending, or repeated vibration measurements kept in a spreadsheet over time, is the best method to track machine health. With 805 you can easily:

  • Export your result to Excel through USB connection
  • Trend the readings with the pre-built Microsoft® Excel templates and plot graphs
  • Compare the overall vibration readings to ISO Standards
    (10816-1, 10816-3, 10816-7)


Vibration Meter
Low frequency range (overall measurement) 10 Hz to 1,000 Hz
High frequency range (CF+ measurement) 4,000 Hz to 20,000 Hz
Severity levels Good, satisfactory, unsatisfactory, unacceptable
Vibration limit 50 g peak (100 g peak-peak)
A/D converter 16-bit
Signal to noise ratio 80 dB
Sampling rate Low frequency 20,000 Hz
High frequency 80,000 Hz
Real time clock backup Coin battery
Sensitivity 100 mV g ±10%
Measurement range 0.01 g to 50 g
Low frequency range (overall measurement) 10 Hz to 1,000 Hz
High frequency range 4,000 Hz to 20,000 Hz
Resolution 0.01 g
Accuracy At 100 Hz ±5% of measured value
Amplitude Units
Acceleration g, m/sec²
Velocity in/sec, mm/sec
Displacement mils, mm
Infrared Thermometer (Temperature Measurement)
Range -20°C to 200°C (-4°F to 392°F)
Accuracy ±2°C (4°F)
Focal length Fixed, at ~3.8 cm (1.5 in)
External sensor
Fluke supports but does not provide external sensors
Frequency range 10 Hz to 1,000 Hz
Bias voltage (to supply power) 20 VDC to 22 VDC
Bias current (to supply power) Maximum 5 mA
External interfaces USB 2.0 (full speed) communication
Data capacity Database on internal flash memory
Upgrade Through USB
Memory Up to 3,500 measurements
Radiated Emission
Electrostatic discharge: burst Standard EN 61000-4-2
Electromagnetic interference Standard EN 61000-4-3
RE Standard CISPR 11, Class A
Operating temperature -20°C to 50°C (-4°F to 122°F)
Storage temperature -30°C to 80°C (-22°F to 176°F)
Operating humidity 10% to 95% RH (non-condensing)
Operating/storage altitude Sea level to 3,048 meters (10,000 feet)
IP rating IP54
Vibration limit 500 g peak
Drop test 1 meter
General Specifications
Battery type AA (2) Lithium Iron Disulfide
Battery life 250 measurements
Size (L x W x H) 24.1 x 7.1 x 5.8 cm (9.5 x 2.8 x 2.3 in)
Weight 0.40 kg (0.89 lb)
Connectors USB mini-B 7-pin, stereo audio output jack (3.5 mm Audio Plug), external sensor jack (SMB connector)


Part Numbers
MCM Part #:105-1195
Fluke Part #:FLUKE-805 FC
Package Specifications & Dimensions
Warranty:90 days
Need to Return?
Length:0 in.
Width:0 in.
Height:0 in.
Shipping Information
Extra Shipping Charge:No
Drop Ship:No

Product Reviews Top

Associated Products

Image of Fluke Connect™ Wireless SD Card

105-1185 - Fluke Connect™ Wireless SD Card

Wirelessly enable your Fluke thermal camera with the Fluke Connect™ wireless SD card and you can instantly upload, share and analyze data from anywhere, with anyone on your team, at any time.

Ships Direct


Buy Now
Image of Fluke Connect™ Processmeter and Thermometer

105-1190 - Fluke Connect™ Processmeter and Thermometer

Combine the power of the 789 and the wireless data logging capabilities of Fluke Connect™ with ShareLive™ video call, and technicians can now do a lot more while carrying a lot less.

Ships Direct


Buy Now
Image of Fluke Connect™ Vibration Tester

105-1200 - Fluke Connect™ Vibration Tester

Fluke 810 helps identify and prioritize mechanical problems. Check out how this hand held vibration tester can help make informed maintenance decisions.

Ships Direct


Buy Now
Image of Fluke Connect™ 3000 Series Wireless Digital Multimeter

105-1205 - Fluke Connect™ 3000 Series Wireless Digital Multimeter

Fluke's 3000 FC Series Wireless Multimeter puts wireless test tools, not your body, near live electrical panels. Improve safety and efficiency with this tester. Measurements are displayed on the multi-line LCD screen, or on your mobile Apple or Android device.

Ships Direct


Buy Now